Send Message
Guangzhou YIGU Medical Equipment Service Co.,Ltd

MP30 3M 5 Line Patient Monitor Repair Parts Excellet Condition

Product Details:
Model Number: MP30
Payment & Shipping Terms:
Minimum Order Quantity: 1/PCS
Price: negotiation
Packaging Details: Carton Box
Delivery Time: within 1 working day after payment confirmed
Payment Terms: TT/, Western Union/paypal
  • Detail Information
  • Product Description

Detail Information

Model: MP30 Shipping Time: Within 1-3work Days
Condition: New And Excellet Price: Negotiate
Payments: TT/Western Union Or Paypal Shipments: DHL/EMS/FedEx
High Light:

MP30 Patient Monitor Repair Parts

,

5 Line Patient Monitor Repair Parts

Product Description

New and good condition MP30 Monitor 3M 5 Line Patient Monitor Repair Parts

 

Brand:

 

Name:New and good condition MP30 Monitor 3M 5 Line

 

 

 

Company Business Scope

  • A. ECG monitor, Fetal monitor, Defibrillator, Electrocardiograph, Oximeter for repairing and accessories for selling.
  • B. Mainboard, Power Stripe/Panel, Touch Screen, Viewing screen, Button Board, ECG/Oximeter/Blood Press Module for repairing and selling.
  • C. Medical Patient Monitor/Electrocardiograph for leasing, maintenance, guarantee repair and exchange.

 

Common Faults Repair

  • 1. Unbootable/ Unable to boot up 2. The module ( M3001A ) can’t detect blood pressure.
  • 3. The module can’t be connected. 4. Automatically disconnect.
  • 5. The sphygmomanometer has a leak. 6. NIBP equipment failure.
  • 7. Unable to contact. 8. Error reporting MMS disconnected.
  • 9. False alarm MMS pull out. 10. Can’t load out.
  • 11. ECG malfunctions. 12. ECG equipment out of order.
  • 13. Software upgrades. 14. NIBP fails to inflate.
  • 15. IBP equipment faults. 16. M3012A module can’t be detected.
  • 17. Automatically restart. 18. The encoder can’t work.
  • 19. Blue screen appears after startup. 20. No ECG signal.
  • 21. Unable to enter the select menu. 22. Alarm occurs when starting up, and the failure light is on.
  • 23. Report CO2 plugging. 24. MMSL developing module faults.
  • 25. M3015A / M3001A module faults. 26. No power display light.
  • 27. NBP equipment faults. 28. ECG and oximeter equipment faults.
  • 29. LCD lamp aging. 30. Inflated blood pressure does not indicate a number.
  • 31. The key plate is out of order. 32. Encoder failure.
  • 33. Can’t inflate. 34. NIBP equipment faults.
  • 35. SP O2 and ECG equipment fault. 36. Unable to charge.
  • 37. The touch screen can’t work. 38. The screen shows double image.
  • 39. Error code 1000. Error code 20004. 40. No alarm sounds.

 

Business Scopes
Repairing Services
Monitor, ECG, Defibrillator, Oximeter, Electrocardiograph, Fetal monitor and spare parts
Sell and Replace Mainboard, Circuit board, Power strip/ panel, Battery, SP O2 and ECG module, Parameter module, Display screen, Touch screen, Encoder, Keyboard plate, Sensor, Probe, Cable etc.
Service Brands
GE, , SPACELABS, SIEMENS, MINDRAY, NIHON KOHDEN, Endoscopy, TYCO, NONIN, TOSHIBA, MEDISON, BIOSOUND, HITACHI, HP, ATL, ALOKA etc.


1. Maintenance Services:


ECG monitor, Defibrillator, Oximeter, Electrocardiograph, Fetal monitor

2. Sell and Replace:


Mainboard, Circuit board, Power strip/ panel, Battery, SP O2 and ECG module, Parameter module, Display screen, Touch screen, Encoder, Keyboard plate, Sensor, Probe, Cable etc.

3. Service Brands:


GE, , SPACELABS, SIEMENS, MINDRAY, NIHON KOHDEN, Endoscopy, TYCO, NONIN, TOSHIBA, MEDISON, BIOSOUND, HITACHI, HP, ATL, ALOKA etc.

 

 

  • Agilent M1460A Sensor, Intellivue G5-M109A, Intellivue MX40,
  • M1205A , M1001A, M1012A, M1034A, M3001A, M3012A,M3014A, M3015A,M3046A,
  • MP2 X2,MP20,MP30, MP40, MP5, MP50 , MP60, MP70, MP80, MP90,
  • V24E(M1204A), VM4, VM6, VM8,VS2+, VS3
GE

 

  • B20, B20i, B30, B40, B40i, B650, B850,
  • DASH1800, DASH2000, DASH2500, DASH3000, DASH5000, Cardiocap 5,
  • Datex-Ohmeda S3/S4/S5, GE DT-4500, Marquette EAGLE 4000,
  • PRO1000, PRO300,
  • SOLAR8000, SOLAR8000i, SOLAR8000M,
  • V100, SAM Smart, SAM80
Nihon Kohden

 

  • BSM-2301A, BSM-2301K, BSM-2304A, BSM-2351A, BSM-2351C, BSM-4104A, BSM-5106A
  • GF-210R, MU-631KA, WEP-4204K, WEP-4208A
Mindray

 

  • IMEC8, IMEC10, IMEC12,
  • IPM8, IPM10, IPM12, IPM9800, MEC-1000, MEC-1200, MEC-200, MPM,
  • PANORAMA, PM6000, PM1000, PM8000, PM8000E, PM9000, PM9000E,
  • T1, T5, T6, T8, VS-800
Spacelabs

 

  • 90309, 90369, 90518,91369, 91370, 91387, 91388, 91393, 91496, 91518,
  • elance93300,mCare300
Siemens
  • SC6002,SC6000,SC7000,SC6002 XL
Tyco
  • NBP4000, NBP4000C

 

Notes from company

  • Orders: Medical spares and accessories with bulk stock and favourable price, and orders could be accepted and arranged anytime.
  •  
  • Payment terms: T/T, Western Union, Paypal are acceptable. 100% prepaid before shipping.
  •  
  • Worldwide Shipping: DHL, UPS, EMS, ACS etc., express is based on buyers’ choice. Orders could be arranged within 1 work day after payment confirmed. Tracking No. could be offered within 1 day after shipment.
  •  
  • Return and repair: Shipping fee for returned item need to be charged half customers and half seller. All second hand unit will be handled by one of our certified and experienced engineer, repair service is possible.

MP30 3M 5 Line Patient Monitor Repair Parts  Excellet Condition 0

Get in touch with us

Enter Your Message

You Might Be Into These