Commercial Used Medical Equipment NIHON KOHDEN WEP 4208A Patient Monitor

Product Details:
Place of Origin: original
Brand Name: NIHON KOHDEN
Model Number: WEP 42088A
Payment & Shipping Terms:
Minimum Order Quantity: 1 unit
Price: accept negotiation
Packaging Details: normal standard package
Delivery Time: within 1-2 business day after payment
Payment Terms: T/T, Western Union,paypal
Supply Ability: 10 sets available
  • Detail Information
  • Product Description

Detail Information

Warranty: 90 Days Condition: Used -excellent Condition
Services: Parts For Selling Or Repairing Stocks: Available
High Light:

used hospital equipment

,

medical accessories

Product Description

NIHON KOHDEN WEP 4208A patient monitor with stock for sale with 90 days warranty hospital devices

 

YIGU Features:

 

1. used goods also with 90 days warranty and in good condition, medical parts show competitive price in the market.

 

 

2. Also accpeting exchanged goods to get the favorable price.

 

 

3.WE have a profesiional engineer have more than 10 years skillful talents in this filed, we can help to repair the goods.

 

 

NO. BRAND MODEL REPAIR PARTS NORMAL PROBLEM
1 MP20 Mainboard,Power Supply 1,can not turn on;
2,blurred screen/Not normal screen display/starting up with logo;
3,Repeatedly restart;
4,can not identify module;
5,MSL Power supply overload;
6,Intermittent fault;
7,Touch screen fault;
2 MP30 Mainboard,Power Supply
3 MP40 Mainboard,Power Supply
4 MP50 Mainboard,Power Supply
5 MP60 Mainboard,Power Supply
6 MP70 Mainboard,Power Supply
7 M3001A Module,Mainboard,PCB
8 M3012A Module
9 M3014A Module
10 M3015A Module
11 M3016A Module
12 M3000-60002 NIBP Module
13 M3000-60003 NIBP Module
14 MP5 Mainboard,Power Supply  
15 VM4 Mainboard,PCB 1,can not turn on;
2,NBP fault;
16 VM6
17 VM8
18 M4735A Mainboard,Power Supply,Defibrillation plate 1.Error code 1
2.Error code 1000
3.can not turn on
4.Mainboard failure
5.Error 20004
6. ECG error
19 GE DASH1800 Module,Mainboard 1.133 error
2.can not charge
3.NIBP can not deflate
4.NIBP signal can not be measured
5.can not turn on
20 GE DASH2500 Module,Mainboard
21 GE DASH3000 Mainboard,DAS module 1.Restar
2.NIBP can not be measured
3.Turn on errot
4.Black screen
5. NIBP fault
22 GE DASH4000
23 GE DASH5000
24 GE SOLAR8000I Mainboard,SAM80 module,TRAM module 1.Invalid keyboard
2.Repeatedly restart
3.Fail Self-checking
4.Cannot detect module
5.SAM module can not be measured
6.NIBP can not inflate
25 GE SOLAR8000M Mainboard,SAM80 module,TRAM module
26 Spacelabs 91369,SL2700,91387,91393,91390 Mainboard,module,PCB 1. The blood oxygen interference
2. The ecg interference
3. The blood pressure 2003 error
4. Check module
5. Restart boot
6. Touch screen failure
7. Unable to boot
8. The power adapter failure
27 Mindray T5 Mainboard,MPM module 1.Can not display the sensor
2.NIBP fault
3.ECG fault
4.Can not measure IBP
5.SPO2 errot
6.ECG initialization error
7.can not turn on
8.LCD errot
9.Long time to turn on
10.Mainboard failure
11. MPM module fault
28 Mindray T6 Mainboard,MPM module
29 Mindray T8 Mainboard,MPM module

 

 

 

Detailed introduction:

 

Selling and replacing for Electrocardiogram Monitoring/ Defibrillator/ EGG/ Fetal Monitor Repair and parts;

 

To detect and judge Chip level Mainboard, Power Supply, ECG PCB, SPO2 PCB,NIBP PCB, Display,

 

Keyboard Plate, Parameter PCB, Rotary Knob;

 

Selling and replacing all kinds of PCB, Power Supply, ECG PCB, SPO2 PCB,NIBP PCB, Display, Keyboard Plate, Parameter PCB, Rotary Knob;

 

Monitor/ Electrocardiograph for renting, maintenance, guarantee repairing and training.

 