Detail Information |
|||
Name: | Patient Monitor M3001A Module Repair And Upgrade | Condition: | Repair |
---|---|---|---|
Warranty: | 90 Days | In Stock: | Yes |
High Light: | patient monitoring system parameters,patient monitor parameters |
Product Description
Brand Name:
Name: patient monitor M3001A module repair and upgrade
Equipment Repair
Advanced: Quick 1 to 2 days turnaround
Repair parts: Mian board, parameter module, power supply etc.,
Common fault: SPO2, ECG, NIBP, device fault;,equipment could not be turned
Flat rate repair pricing available
Number | Brand | Type | Maintenance Parts | Common Fault |
1 | MP20 | Mainboard,Power Supply | 1,can not turn on; 2,blurred screen/Not normal screen display/starting up with logo; 3,Repeatedly restart; 4,can not identify module; 5,MSL Power supply overload; 6,Intermittent fault; 7,Touch screen fault; |
|
2 | MP30 | Mainboard,Power Supply | ||
3 | MP40 | Mainboard,Power Supply | ||
4 | MP50 | Mainboard,Power Supply | ||
5 | MP60 | Mainboard,Power Supply | ||
6 | MP70 | Mainboard,Power Supply | ||
7 | M3001A | Module,Mainboard,PCB | ||
8 | M3012A | Module | ||
9 | M3014A | Module | ||
10 | M3015A | Module | ||
11 | M3016A | Module | ||
12 | M3000-60002 | NIBP Module | ||
13 | M3000-60003 | NIBP Module | ||
14 | MP5 | Mainboard,Power Supply | ||
15 | VM4 | Mainboard,PCB | 1,can not turn on; 2,NBP fault; |
|
16 | VM6 | |||
17 | VM8 | |||
18 | M4735A | Mainboard,Power Supply,Defibrillation plate | 1.Error code 1 2.Error code 1000 3.can not turn on 4.Mainboard failure 5.Error 20004 6. ECG error |
|
19 | GE | DASH1800 | Module,Mainboard | 1.133 error 2.can not charge 3.NIBP can not deflate 4.NIBP signal can not be measured 5.can not turn on |
20 | GE | DASH2500 | Module,Mainboard | |
21 | GE | DASH3000 | Mainboard,DAS module | 1.Restar 2.NIBP can not be measured 3.Turn on errot 4.Black screen 5. NIBP fault |
22 | GE | DASH4000 | ||
23 | GE | DASH5000 | ||
24 | GE | SOLAR8000I | Mainboard,SAM80 module,TRAM module | 1.Invalid keyboard 2.Repeatedly restart 3.Fail Self-checking 4.Cannot detect module 5.SAM module can not be measured 6.NIBP can not inflate |
25 | GE | SOLAR8000M | Mainboard,SAM80 module,TRAM module | |
26 | Spacelabs | 91369,SL2700,91387,91393,91390 | Mainboard,module,PCB | 1. The blood oxygen interference 2. The ecg interference 3. The blood pressure 2003 error 4. Check module 5. Restart boot 6. Touch screen failure 7. Unable to boot 8. The power adapter failure |
27 | Mindray | T5 | Mainboard,MPM module | 1.Can not display the sensor 2.NIBP fault 3.ECG fault 4.Can not measure IBP 5.SPO2 errot 6.ECG initialization error 7.can not turn on 8.LCD errot 9.Long time to turn on 10.Mainboard failure 11. MPM module fault |
28 | Mindray | T6 | Mainboard,MPM module | |
29 | Mindray | T8 | Mainboard,MPM module |