Send Message
Guangzhou YIGU Medical Equipment Service Co.,Ltd

GE Dash 2500 Patient Monitor Module Repair / Ultrasound Probe For Patient Monitoring Systems

Product Details:
Brand Name: GE
Model Number: DASH2500
Payment & Shipping Terms:
Minimum Order Quantity: 1pc
Price: Negotiation
Packaging Details: Shipped within 1 working day after payment received
Payment Terms: T/T or Paypal, Western Union
  • Detail Information
  • Product Description

Detail Information

Name: DASH 2500 Patient Monitor Module Repair Condition: Repair,used
Warranty: 90 Days In Stock: Yes
High Light:

medical accessories

,

patient monitor parameters

Product Description

 

  • Description:

Brand Name: GE

Name: GE DASH 2500 patient monitor module repair

       Equipment Repair

 

Advanced: Quick 1 to 2 days turnaround

Repair parts: Mian board, parameter module, power supply etc.,

Common fault: SPO2, ECG, NIBP, device fault;,equipment could not be turned 

Flat rate repair pricing available

 


Patient Monitor/Defibrillator/Fetal Monitor/ECG/EKG
BRAND
MODEL
GE DASH1800,DASH2000,DASH2500,DASH3000,DASH4000,DASH5000,
SOLAR8000,SOLAR8000i,SOLAR8000M
(TRAM 400A,451N,451SL,450SL,851N,TEMP 400,SAM,SAM80),
Datex-Ohmeda,AS/3,S/4,S/5,Cardiocap/5,
B20,B20i,B30,B40,CAM,Transport Pro,B650,B850
(M-NESTR,M-NETPR,M-P,M-EST,M-NIBP,E-PSM,E-COPSV,E-PT,
E-MEM,SL-CAIO,E-NSATX,E-miniC,E-PP,E-PRESTN)
PRO300,PRO400,PRO1000,V100 AGLE1000,EAGLE3000,EAGLE4000
MP20,MP30,MP40,MP50,MP60,MP70,MP80,MP90,FM20,M4735A,M1351A,
M1355A,M1205A V24C
(M3000A,M3001A,M3012A,M3014A,M3015A,M3016A,M1013A,M3000-60001,M3000-60002,M3000-60003),
A1,A3,C1,C3,M2,M3046A, VM4,VM6,VM8,VS3, MP2,MP5,IntelliVue X2
NIHON KOHDEN
BSM-1753,BSM-4102A,BSM-4104A,BSM-4114A,BSM-5135A,
BSM-5136A,BSM-5106A,BSM-6301A,BSM-6701A,BSM-2350,BSM-2351,
BSM-2351A,BSM-2351C,BSM-2303,BSM-2354A,BSM-2301A,
BSM-2304A,WEP-4208A,MU-631RA
Spacelabs 1050,90369,91369,Ultraview SL, 0496,91496,mCare300
Siemens SC60002,SC6000,SC7000,SC60002XL
Mindray PM-6000,PM-7000,PM-8000,PM-9000,MEC-1000,MEC-2000,
PM-7000Express,PM-8000Express,PM-9000Express,PM-6000,VS-800,
VS-900,BeneView T5,BeneView T6,BeneView T8
PM-60
Tyco NBP4000,NBP4000C

SPO2 oximeter Repair
BRAND
MODEL
GE Ohmeda TuffSat ,Ohmeda 3900
Tyco NBP-40,N-65,NBP-390,N-395,N-550,N-560,
N-595,N-600,N-600x
Rad-8 SPO2 oximeter ,Radical-7(MS-2011,MS-11,MS-7,MS-5)

 

NIHON KOHDEN

BSM-1753A

 

 

Monitoring Equipment

 

1. Selling and replacing for Electrocardiogram Monitoring/ Defibrillator/ EGG/ Fetal Monitor Repair and parts.

 

2. Inspection Judgment/ Chip/Mainboard, Power Supply, ECG PCB, SPO2 PCB,NIBP PCB, Display,Keyboat Plate, Specification PCB, Rotary Knob Maintenrance.

 

3.Selling and replacing all kinds of PCB, Power Supply, ECG PCB, SPO2 PCB,NIBP PCB, Display,Keyboat Plate, Specification PCB, Rotary Knob.

 

4.Monitor/ Electrocardiograph for renting,maintenance, guarantee repairing and training.

Included brands: GE, , Spacelabs, Siemens, Mindray, ZOLL, Endoscopy, Tyco, NIHON KOHDEN, , Promeco etc.

 

Number Brand Type Maintenance Parts Common Fault
1 MP20 Mainboard,Power Supply 1,can not turn on;
2,blurred screen/Not normal screen display/starting up with logo;
3,Repeatedly restart;
4,can not identify module;
5,MSL Power supply overload;
6,Intermittent fault;
7,Touch screen fault;
2 MP30 Mainboard,Power Supply
3 MP40 Mainboard,Power Supply
4 MP50 Mainboard,Power Supply
5 MP60 Mainboard,Power Supply
6 MP70 Mainboard,Power Supply
7 M3001A Module,Mainboard,PCB
8 M3012A Module
9 M3014A Module
10 M3015A Module
11 M3016A Module
12 M3000-60002 NIBP Module
13 M3000-60003 NIBP Module
14 MP5 Mainboard,Power Supply  
15 VM4 Mainboard,PCB 1,can not turn on;
2,NBP fault;
16 VM6
17 VM8
18 M4735A Mainboard,Power Supply,Defibrillation plate 1.Error code 1
2.Error code 1000
3.can not turn on
4.Mainboard failure
5.Error 20004
6. ECG error
19 GE DASH1800 Module,Mainboard 1.133 error
2.can not charge
3.NIBP can not deflate
4.NIBP signal can not be measured
5.can not turn on
20 GE DASH2500 Module,Mainboard
21 GE DASH3000 Mainboard,DAS module 1.Restar
2.NIBP can not be measured
3.Turn on errot
4.Black screen
5. NIBP fault
22 GE DASH4000
23 GE DASH5000
24 GE SOLAR8000I Mainboard,SAM80 module,TRAM module 1.Invalid keyboard
2.Repeatedly restart
3.Fail Self-checking
4.Cannot detect module
5.SAM module can not be measured
6.NIBP can not inflate
25 GE SOLAR8000M Mainboard,SAM80 module,TRAM module
26 Spacelabs 91369,SL2700,91387,91393,91390 Mainboard,module,PCB 1. The blood oxygen interference
2. The ecg interference
3. The blood pressure 2003 error
4. Check module
5. Restart boot
6. Touch screen failure
7. Unable to boot
8. The power adapter failure
27 Mindray T5 Mainboard,MPM module 1.Can not display the sensor
2.NIBP fault
3.ECG fault
4.Can not measure IBP
5.SPO2 errot
6.ECG initialization error
7.can not turn on
8.LCD errot
9.Long time to turn on
10.Mainboard failure
11. MPM module fault
28 Mindray T6 Mainboard,MPM module
29 Mindray T8 Mainboard,MPM module

 

Project Advantages: More 100pcs used B Ultrasound Probe off the shelf for renting and back up.

 

 

 

Ultrasound

 

BRAND MODEL
GE Voluson E6 ,VolusonE8,LOGIQ180,LOGIQ200,LOGIQ400,LOGIQ500,LOGIQ3,LOGIQ5,LOGIQ7,LOGIQ9,LOGIQ E,LOGIQ BOOK XP,VIVID3,VIVID4,VIVID5,,VIVID i, VIVID E9,VIVID 7

IU22,IE33,,D3,HD6,HD7,HD9,HD11,HD15,HD11XE,

HDI4000,HDI5000,SONOS4500,SONOS5500,Envisor

SIEMENS ACUSON X150 ,ACUSON X300,ACUSON X300 PE,SONOLINE G20 ,SONOLINE G40,SONOLINE G50,SONOLINE G60,PRIMIER,Sequoia 512,Acuson CV70,Sonoline Premier(G40),acuson_antares
MEDISON
SA-6000,SA-1500,SA-4500,SA-4800,SA-3200,SA-5000,SA5500, SA-8000,SA8800,SA9900
Mindray DP3300,DP6600,DP7700,DP8800,DP9900,N80, M5,DC-3, DC-6
ESAOTE AU3,AU4,AU5,DU3,DU4,DU5,DU8

 

SONOSITE

 

TITAN
ALOKA

Prosound SSD-4000,SSD-240,SSD-260,SSD-280,

SSD-633,SSD-650,SSD-725,SSD-830,SSD-870,SSD-1000,SSD-1400,SSD-1700,SSD-5000,SSD-7000

Toshiba

SSA-770A,SSA-580,SSH-140,SSA-270A,SSA-340A,SSA-350A,SSA-270,SSH-140A,250A nemio17

 

 

GE Dash 2500 Patient Monitor Module Repair / Ultrasound Probe For Patient Monitoring Systems 0

Get in touch with us

Enter Your Message

You Might Be Into These