Send Message
Guangzhou YIGU Medical Equipment Service Co.,Ltd

11.1V 4500mAh Medical Equipment Batteries Mindray BeneView T5 T6 T8 , Patient Monitor Origianl Battery

Product Details:
Place of Origin: original
Brand Name: Mindray
Model Number: T5 T6 T8 LI23S002A
Payment & Shipping Terms:
Minimum Order Quantity: 1 pcs
Price: accept negotiation
Packaging Details: normal standard package
Delivery Time: within 1-2 business day after payment
Payment Terms: T/T, Western Union,paypal
Supply Ability: 20 pcs available
  • Detail Information
  • Product Description

Detail Information

Stock: Yes Pn: LI23S002A
Suitable Model: T5 T6 T8 Condition: Origianl And Completely New
Warranty: 90 Days Brand: Mindray
High Light:

medical battery

,

medical batteries

Product Description

Medical batteries Mindray BeneView T5 T6 T8 Patient Monitor Origianl Battery LI23S002A parameter:DC 11.1V=4500mAh 49

 

YIGU Medical operating methods:

  • Notes from company:

Order: Medical parts and equipment with bulk stock and competitive price, order could be accepted and arranged in the short time.
Payment: 100% prepaid before shipping. Bank transfer / western union / paypal are acceptable.

 

Shipping: Worldwide shipping. Order could be arranged within 1 working day after payment confirmed. DHL, UPS, EMS, ACS etc., express is based on your choice.


Tracking No. could be offered within 1 day after shipment.


Return and repair: Shipping fee for returned item need to be charged half customers and half seller.

 

 


All second hand unit will be handled by one of our certified and experienced engineer, repair service is possible.

 

 

YiGu Medcial Advantages:

 

1. have powerful supplier, with stable goods sources

 

2. own professional engineer with over 10 years skillful talents

 

3.goods with 90 days, turnover rate is fast

 

4.providing high quality and trustable service and goods,which can establish good relationship with all over the world.

 

Our support:

  1. Stable production resources and the skillful engineer with over 10 years experience in medical repairing field.

 

  1. Reliable support from our clients from all over the world, cause we can provide the qualified and guaranteed production, within 90 days warranty, fast turn-back rate for our customers.

 

  1. Our after sales service can reach client’s demand, once it occurs some problems, we can provide some assistance or try to solve it in our best effort.
NO. BRAND MODEL REPAIR PARTS NORMAL PROBLEM
1 MP20 Mainboard,Power Supply 1,can not turn on;
2,blurred screen/Not normal screen display/starting up with logo;
3,Repeatedly restart;
4,can not identify module;
5,MSL Power supply overload;
6,Intermittent fault;
7,Touch screen fault;
2 MP30 Mainboard,Power Supply
3 MP40 Mainboard,Power Supply
4 MP50 Mainboard,Power Supply
5 MP60 Mainboard,Power Supply
6 MP70 Mainboard,Power Supply
7 M3001A Module,Mainboard,PCB
8 M3012A Module
9 M3014A Module
10 M3015A Module
11 M3016A Module
12 M3000-60002 NIBP Module
13 M3000-60003 NIBP Module
14 MP5 Mainboard,Power Supply  
15 VM4 Mainboard,PCB 1,can not turn on;
2,NBP fault;
16 VM6
17 VM8
18 M4735A Mainboard,Power Supply,Defibrillation plate 1.Error code 1
2.Error code 1000
3.can not turn on
4.Mainboard failure
5.Error 20004
6. ECG error
19 GE DASH1800 Module,Mainboard 1.133 error
2.can not charge
3.NIBP can not deflate
4.NIBP signal can not be measured
5.can not turn on
20 GE DASH2500 Module,Mainboard
21 GE DASH3000 Mainboard,DAS module 1.Restar
2.NIBP can not be measured
3.Turn on errot
4.Black screen
5. NIBP fault
22 GE DASH4000
23 GE DASH5000
24 GE SOLAR8000I Mainboard,SAM80 module,TRAM module 1.Invalid keyboard
2.Repeatedly restart
3.Fail Self-checking
4.Cannot detect module
5.SAM module can not be measured
6.NIBP can not inflate
25 GE SOLAR8000M Mainboard,SAM80 module,TRAM module
26 Spacelabs 91369,SL2700,91387,91393,91390 Mainboard,module,PCB 1. The blood oxygen interference
2. The ecg interference
3. The blood pressure 2003 error
4. Check module
5. Restart boot
6. Touch screen failure
7. Unable to boot
8. The power adapter failure
27 Mindray T5 Mainboard,MPM module 1.Can not display the sensor
2.NIBP fault
3.ECG fault
4.Can not measure IBP
5.SPO2 errot
6.ECG initialization error
7.can not turn on
8.LCD errot
9.Long time to turn on
10.Mainboard failure
11. MPM module fault
28 Mindray T6 Mainboard,MPM module
29 Mindray T8 Mainboard,MPM module

 

detailes of the production:

 

11.1V 4500mAh Medical Equipment Batteries Mindray BeneView T5 T6 T8 , Patient Monitor Origianl Battery 0

Get in touch with us

Enter Your Message

You Might Be Into These